Sign In | Join Free | My spintoband.com
China Tianjin Estel Electronic Science and Technology Co.,Ltd logo
Tianjin Estel Electronic Science and Technology Co.,Ltd
TIANJIN ESTEL ELECTRONIC SCIENCE AND TECHNOLOGY CO.,LTD We are the professoinal supplier of outdoor telecom cabinet, air conditioner, heat exchanger, and telecom power system.
Verified Supplier

9 Years

Home > Industrial Power Supplies >

Commercial Power Supply , Professional Power Supply ISO9001 CE Certification

Tianjin Estel Electronic Science and Technology Co.,Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment

Commercial Power Supply , Professional Power Supply ISO9001 CE Certification

Brand Name : ESTEL

Model Number : GPAD461M54-1A

Certification : ISO9001, CE, 3C, FCC, TLC

Place of Origin : Shenzhen, China (Mainland)

MOQ : 1

Price : negotiation

Payment Terms : L/C, T/T, D/A, D/P, Western Union

Supply Ability : 20,000 sets per month

Delivery Time : 7-10 working days

Packaging Details : carton/wooden case

Application : industrial equipment

Input Voltage : 145~300Vac

Max. Output Current : 4A

Output Voltage : +53.5Vdc, +12Vdc

Power Factor : 0.95

Output Power : 464W

Product Name : Industrial Power Supplies

Contact Now

Commercial Power Supply , Professional Power Supply ISO9001 CE Certification

Quick Details:

Place of Origin: Shenzhen, China (Mainland) Input Voltage: 145~300Vac
Brand Name: ESTEL Output Voltage: +53.5Vdc, +12Vdc
Model Number: GPAD461M54-1A Output Power: 464W
Product Name: Industrial Power Supplies Input Frequency 47~63Hz
Certification: ISO9001, CE, UL Max. Input Current:4A
Application: industrial equipment Power Factor: 0.95

Payment & Shipping Terms:

Minimum Order Quantity: 1 set
Price: negotiation
Payment Terms: L/C, D/A, D/P, T/T, Western Union
Supply Ability: 20,000 sets per month
Delivery Time: 7-10 working days
Packaging Details: carton/wooden case

1. Description

The GPAD461M54-1A custom made industrial power supplies supports wide input voltage range (145Vac ~ 300Vac), compatible with 220Vdc~380Vdc input; with two ways output: +53.5Vdc, +12Vdc. The power system includes various protection and alarm: over-voltage protection, under-voltage protection, over-current protection, short-circuit protection, over-temperature protection, input/output alarm. The power supply is designed strictly in accordance with the safety regulations, which conforms to the safety standards and requirements of information technology.

2. Technical Parameters

Ambient conditions
Parameters Min Typical Max Unit Note
Operating temperature -40 75 °C
Storage temperature -40 85 °C
Relative humidity 10 95 % non-condensing
Atmospheric Pressure 70 106 KPa normal operation
Cooling Device natural conduction cooling

Input
Parameter Min Typical Max Unit Note
AC input voltage range 145 220 300 Vac The power supplies can work normally at ambient temperature range: -40 °C~+75 °C
AC input start voltage range 150 220 285 Vac The power supplies can start normally at ambient temperature range: -40 °C~+75 °C
DC input start voltage range 220 380 Vdc
Max input current 4 A 145Vac input
Input surge current 40 A 300Vac input,25°C
AC input voltage frequency range 47 50/60 63 Hz
Input power factor 0.95 220Vac input, rated load

Basic output characteristics
Parameter Min Typical Max Unit Note
Output voltage 53.5 Vdc
12
Output voltage range +53.5V 50 57 Vdc
+12V 11.5 12.5
Output rated current range +53.5V 0 8..5 A
+12V 0 3.0
Voltage regulation accuracy +53.5V ±1.5 %
+12V ±2
Load regulation +53.5V ±1.5 %
+12V ±2
Line regulation +53.5V ±1 %
+12V ±2
Noise +ripple (peak to peak value) +53.5V 150 Vp-p
200 (Low temperature-40°C)
+12V 150
200 (Low temperature-40°C)

Other output characteristics
Parameter Min Typical Max Unit Note
Output power 464 W
Output efficiency 88 % Rated voltage/rated load
85 Full temperature range/full voltage range/rated load
Turn-on output delay Normal temperature 3s, low temperature 5s s 220Vac input, full load output
Output rise time 200 ms Output voltage rise from 10% to 90%, rated load
Output overshoot 5 % +12Vdc and 53.5Vdc
Temperature coefficient ±0.02 %/°C

Protection
Parameter Min Typical Max Unit Note
Input over-voltage protection 305 330 Vac Each output with 50% load
Input over-voltage protection recovery 290 310 Vac Each output with 50% load
Input under-voltage protection 125 140 Vac
Input under-voltage protection recovery 141 150 Vac
Output over-voltage protection (53.5Vdc) 58 62 Vdc Self-recovery,each output with 50% load
Output over-voltage protection (12Vdc) 13.8 18.5 Vdc Self-recovery, not affect 53.4vdc output
Output current-limiting protection(53.5Vdc) 10 15.5 A Self-recovery
Output current-limiting protection (12Vdc) 4 7 A Self-recover,not affect 53.5Vdc output
Output short-circuit protection For long time short-circuit, self-recovery, +12Vdc shot-circuit not affect 53.5Vdc output.
Over-temperature protection No protection within normal working temperature

EMC and others
Parameter Requirement Standard
CE CLASS B EN55022
RE CLASS B EN55022
SURGE Line-line 2kV; line-earth 4kV GB/T 17626.5 Criterion A
EFT LEVEL 3: 2kV GB/T 17626.4 Criterion A
DIP

Fall to 70%,40%,0%

duration: 10ms,100ms, 5000ms etc

EN61000-4-11

GB/T 17626.8

Criterion A( when exceed power input voltage range, select criterion B)
ESD Contact discharge:±8kV. Air discharge: ±8kV GB/T 17626.4 Criterion A
CS LEVEL 2:3V/m field intensity EN61000-4-6
RS LEVEL 2:3V/m field intensity GB/T 17626.3
Current Harmonic Emission

EN 61000-3-2

GB 17625.1

For AC power supply
Voltage Fluctuation And Flicker Pst value not more than 1.0; P1t values not more than 0.65; relative steady voltage change not more than 3%; the largest relative voltage change dmax not more than 4%; time of voltage change device d (t) value more than 3% not longer than 200 ms

EN 61000-3-3

GB 17625.2

For AC power supply
AC Input Llightning Protection 8/20μs waveform; line-line(5 times)5kA, line-earth(5 times)5kA GB/T 17626.5, Criterion B

Other requirements
Parameter Technical requirements
High temperature aging Ambient temperature +55°C, 80% load, power on lasts 48 hours, the power supply should be able to work normally; take out and cool for 2 hours, the power supply should be able to work normally. Output work normally, with stable performance, no alarm
Vibration Sample can bear 5Hz~500Hz random vibration at three mutually perpendicular directions, 5 hz ~ 10 hz frequency range, acceleration spectral density: 10m2/s3; 10Hz-200Hz freqrency range, acceleration spectral density: 3m2/s3; 200Hz-500Hz frequency range, acceleration spectral density: 1m2/s3; 20mins at each direction.(GB/T 2423.11)

After vibration, the power supply should be able to work normally,

normal output, stable performance, without alarm

Shock Half sine wave, acceleration: 20g, pulse width: 11ms, X, Y, Z three directions: 3 times at each direction.(GB/T 2423.5) After shock, the power supply should be able to work normally.
Failure isolation After power module fails without output, the module is isolated, shall not do any harm on equipments and people Power supply module failure should not affect the power supply system
Component Requirements The inner components of power module must use industrial grade components.
Noise 45dB(A), test distance: 1m
Smell No peculiar and harmful smell
Environment Protection RoHS6
MTBF 100000h

Safety and insulation grade
Parameter Level Standard requirement Test conditions
Safety certification Design compliant with IEC60950,UL60950 and EN60950. Finished product have CE Certificate.

IEC60950

UL60950

EN60950

Insulation voltage

(input to output)

1500Vac

GB4943

GB/T13722

Bear 50Hz,1500V AC voltage for 1 minute, leakage current≤10mA, no flashover, no breakdown

Insulation voltage

(input to earth)

1500Vac
Insulation voltage(output to earth ) 500Vdc Bear 500V DC voltage for 1 minute,leakage current≤10mA, no flashover, no breakdown
Insulation resistance >10MΩ EN60065 Under normal atmospheric pressure, relative humidity 90%, testing voltage 500Vdc conditions, the insulation resistance of rectifier main circuit AC/DC part to earth, and AC part to DC part shall be no less than 10MΩ.
Grounding resistance <0.1Ω GB4943
Contact current <3.5mA GB4943

Mechanical specifications
L×W×H (mm) As the following diagram
Weight(kg) ≤1.3Kg

Commercial Power Supply , Professional Power Supply ISO9001 CE Certification

3.Signal

Commercial Power Supply , Professional Power Supply ISO9001 CE Certification

Terminal definition table
Terminal no. Pin no. (from left to right) Screen printing Output voltage definition Note
Input terminal 1 L AC input live wire Interface use VH5.08-3P connector
2 N AC input neutral wire
3 PE Earthing
Output terminal 1 +53.5V 53.5V output + Interface use VH5.08-4P connector and VH5.08-2Pconnector
2 +53.5V 53.5V output +
3 GND 53.5V Output earth
4 GND 53.5V output earth
5 +12V 12Vdc output +
6 GND 12Vdc output earth
Monitoring terminal 1 AC/OK AC input alarm signal 2001S-3P(Pin pitch 2.54mm, Pin diameter 0.64mm)
2 DC/OK DC output alarm signal
3 GND Alarm earth

4. Packing and Shipping

Commercial Power Supply , Professional Power Supply ISO9001 CE Certification

Our Delivery Agent

The goods can be shipped by sea, by air, by courier, by land, by train, etc.

Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.

5. Our Contact Information

Mobile Phone: 0086-13752765943

Telephone: 0086-0755 66600941

Email: info@estel.com.cn

lxf.estel@hotmail.com
Skype: fiona.liang10


Product Tags:

industrial power supply

      

server power supply

      
Wholesale Commercial Power Supply , Professional Power Supply ISO9001 CE Certification from china suppliers

Commercial Power Supply , Professional Power Supply ISO9001 CE Certification Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Tianjin Estel Electronic Science and Technology Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0